Pacific Digital RI-310e Power Supply User Manual


 
Pacific Research Solutions RI-300e User Manual
Page 65
Tone Generator Command Descriptions
TG1 Tone generator #1, you can independently control frequency and level of this generator.
TG2 Tone generator #2, you can independently control frequency and level of this generator.
TONE Predefined tones, used to set the frequency of the tone generator.
DIR. FREQ. Sets the frequency of the tone generator directly. This command selects the most significant digit of the
frequency, followed by a second tone generator command (31 XXX) that control the three least
significant digits of the actual frequency.
LEVEL Sets the modulation level of the tone generator. “50” is full modulation (5 KHz deviation).
CW SPEED Sets the speed of any CW characters following this command.
CW… A specified list of Morse code characters used in a message
TONE ON Turn on the currently configured tone generator to the defined destination.
TONE OFF Turn off the currently configured tone generator to the defined destination.
TONE ON FOR... Sets the amount of time for the tone generator to be on.
DELAY FOR… Sets the amount of delay between tone generator commands.
Note: When setting tone generator levels for generating DTMF digits, set TG1 to Level 15 (31 079) and TG2 to Level 12
(31 162). This will provide the correct amount of twist needed for reliable decode.
SYNTAX: 31 [CW Command]
READ BACK: 31 * [CW Command]
STORAGE: EEPROM
PARAMETERS: 3 digit tone generator commands ranging from 000 to 344, see tone generator commands below
DEFAULT: See default messages below.
EXAMPLE: See example in section 9.
Default Messages, Speech and Tone Generator
Start line 019 31 039 079 118 279 C D Normal courtesy - Tone Generated
Start line 020 31 027 079 165 282 C D Weak signal courtesy - Tone Generated
Start line 021 30 166 393 485 C D Power on reset courtesy “RST”- Speech Synthesized
Start line 022 31 053 079 165 118 272 326 130 290 C D Post timeout - Tone Generated
Start line 024 31 118 043 079 294 039 294 C D Pre timeout - Tone Generated
Start line 025 30 617 217 C D Function error “ERROR” - Speech Synthesized
Start line 026 31 041 079 118 324 216 246 242 C D Function acknowledgment “OK” - Tone Generated
Start line 028 31 118 089 049 326 272 316 055 316 049 Auto patch ring – Tone Generated
316 055 316 055 316 049 316 055 280 C D
Start line 031 31 118 099 043 304 C D A 10 Second test tone @1KHz - Tone Generated.
Start line 032 31 118 079 049 272 318 271 310 039 282 C D Un-lock courtesy - Tone Generated
Start line 034 30 005 429 214 571 216 169 C D Auto patch answer message “HELLO”- Speech Syn.
Start line 035 30 005 617 077 073 C D Auto patch function ack. “OK” - Speech Synthesizer
Start line 036 30 005 617 217 C D Auto patch function “ERROR” - Speech Synthesizer
Start line 037 31 005 027 078 165 295.C D Auto patch ring back - Tone Generated
Start line 038 31 036 079 118 212 239 236 243 243 246 C D Station ID "HELLO" - Tone Generated