Polycom 14117800 Server User Manual


 
128 Configuring KIRK Wireless Server 600v3
14117800, Ed.2.6
•In the Alternative Gatekeeper field, type an alternative IP address of your call
handler (optional).
Contact your system administrator for more information.
•From the Protocol list, select either H323, SIP or Skinny depending on the
protocol you are using.
3 In the System area:
•In the AC field, type an authentication code (optional).
•From the Subscriptions list, select either Allow Anonymous, With User AC only,
or Disabled.
Note: It is recommended to select With User AC only. When subscribing a new
handset to the system it is possible to use an authentication code (AC). If you
want to use the authentication code, you must select With User AC only. For
more information about subscription of handsets and authentication codes, refer
to “Subscribing Handsets” on page 152.
•From the Coder list, select a voice compression value that matches your
telephony infrastructure.
Contact your system administrator for more information.
Note: The voice compression value is not exclusive and the KWS600v3 is not
forced to use the coder.
•From the Tones list, select a ring tone.