Polycom 14117800 Server User Manual


 
Installing the KIRK Wireless Server 600v3 47
KIRK Wireless Server 600v3 Installation and Configuration Guide
Note: To expand a coverage area with KWS600v3, additional radio units must be placed
in such a way that overlap between the different KWS600v3 radio coverage is
established. It is recommended that the overlap is at least 10 to 15 meters/32.8 to 49.2
feet.
Note: D
o not paint the KWS600v3 as paint contains material which can cause decreased
radio coverage.
4.3.1 KIRK Wireless Server 600v3 Indoor Wall Mounting
For best RF coverage, the KWS600v3 must be mounted vertically on walls.
Caution: The KWS6
00v3 must not be installed at any angle other than vertical. If the
KWS600v3 is placed upside-down, the coverage area of the KWS600v3 is decreased by 40
- 50% and it might not transmit or receive effectively.
Caution: D
o not mount the KWS600v3 on soft surfaced walls such as those covered with
canvas or sponge-like materials.
To install the KWS600v3 indoors:
1 Mo
unt the KWS600v3 on the wall, using the anchors and screws provided.
Note: When
you place the KWS600v3 on the screws, ensure that the screws do not
touch the printed circuit board.
Figure 11 Wireless Server 600v3 Wall Mounting
2 Connect the wire into the RJ45 plug on the KWS600v3.