determines whether the DECT radio code PCS04fd was already installed. If this is not the
case, the current DECT radio code is downloaded from the address 192.168.0.10/firm/
ccfp1200.bin, the UPDATE/BMC internal variable is overwritten with PCS04fd and,
finally, the device is reset as soon at it is not being actively used.
13.5.6 SCFG Command
mod cmd UP0 scfg <url> [<final-command> <save-serial> [ /force <hours> ]]
This will cause the device to upload its current configur
ation to <url>. This will be done
using an HTTP PUT command. <url> must be writable thus. Within <url>, some meta
character strings are replaced as follows:
Sequence Replaces Example
#F kernel build number 08-12345
#B boot code build number 401
#H hardware build 102
#h Device hardware number P1200-03-0d-f0
#m MAC address of the device 00-90-33-03-0d-f0
#d Current date and time 20051010-170130
#bn rolling backup index 3
#i (one of) the local ip-address(es) 192.168.0.1
The rolling backup index loops over 0 .. n-1 for each backup.
Beginning with V7.00 the optional Parameters <final-command>, <save-serial> and /
force <hou
rs> will be recognized.
<final-command> defines the command to be executed after successful completion of
scfg
(typically no-op is used).
<save-serial> is compared to the UPDATE/SCFG variable. If
it is not equal, the
command is started. If it is equal and /force is not specified the command is skipped,
otherwise /force is evaluated.
/force <hours> specifies the number of hours after which scfg is executed again even if
<s
ave-serial> has not changed.
mod cmd UP0 scfg http://192.168.0.10/configs/saved/#h
#b5.txt no-op WEEKLY /force 168