Printronix LQH-HWTM Printer User Manual


 
112
Chapter 3 Bar Codes
PDF Optional parameter to enable printing of the human
readable data field. Enter PDF to print the data
field. If the parameter is not used, the human
readable data will not print. This parameter is not
allowed if a null data field was specified.
LOC
Optional parameter to identify the location of the
printable data field. The default value is B, locating
the human readable data below the bar code. A
locates the printable data field above bar code. To
compensate for printing the 0.1-inch high data, the
height of the bar code body is reduced 0.1 inch.
FONT
Optional parameter to select the font for the human
readable data field. Enter O to select OCR-A font;
enter X to select OCR-B font; enter N to select 10
cpi; enter P to select 12 cpi; enter Q to select 13
cpi; enter R to select 15 cpi; enter T to select 17 cpi;
enter V to select 20 cpi.
STOP Ends the Bar Code command while the IGP
continues in the Create Form mode. Enter STOP. If
STOP is not entered, an error message results.