262
Chapter 6 IGP/PGL Emulation Error Codes
Horizontal Line Errors
01 HORiZontal line starting row SR out of bounds
The row specified by the second parameter in the horizontal line
command places the horizontal line outside the boundaries of the
form.
02 HORiZontal line starting column SC out of bounds
The left (starting) column of the horizontal line specified by the
third parameter in the horizontal line command places the
horizontal line outside the boundaries of the form.
03 HORiZontal line ending column EC out of bounds
The right (ending) column of the horizontal line specified by the
fourth parameter in the horizontal line command places the
horizontal line outside the boundaries of the form.
04 HORiZontal line format or delimiter error
Some type of format or delimiter error was detected in the
parameters of the horizontal line command. This error is usually
caused by one or more of the following:
a. A missing semicolon;
b. A colon in place of a semicolon;
c. Too many or too few parameters in the command string;
d. Alpha characters instead of numeric characters in the
parameters.
05 Insufficient memory to store the HORiZontal line
No more room in the IGP memory exists for another horizontal
line. The rest of the horizontal line commands are flushed until
the Stop command is found. Processing will then continue
normally. To create space in the IGP memory, delete forms with
horizontal line elements that are no longer required.
06 HORiZontal line starting column SC > ending column EC
The left (starting) column parameter of the horizontal line
command is greater than or equal to the right (ending) column
parameter.
07 HORiZontal line thickness LT error
The thickness of the horizontal line specified by the first
parameter in the horizontal line command is incorrect. This error
is usually caused by specifying a thickness of zero.
08-09 Not defined.