Printronix LQH-HWTM Printer User Manual


 
Logo Errors
267
49 ALPHA compression factor Cn error (10, 10A, 10B, 12, 13, 15,
17 or 20)
The optional compression parameter (C
n
) which defines the
horizontal pitch of the text was specified incorrectly. The pitches
available are 10, 10A, 10B, 12, 13, 15, 17 and 20.
Logo Errors
50 LOGO horizontal width HL > 240 or dot col > HL
a. The horizontal width of the logo is equal to zero or greater than
240. The IGP automatically reverts to Normal mode when this
occurs.
b. A dot position specified in the logo program exceeds the
specified horizontal width of the logo. When this occurs, the
buffer is flushed until a line terminator is found, and then logo
construction continues normally.
51 LOGO vertical length VL > 252 or dot row n > VL
a. The vertical length of the logo is equal to zero or greater than
252. The IGP automatically reverts to Normal mode when this
occurs.
b. A dot row specified in the logo program exceeds the specified
vertical length of the logo. When this occurs, the buffer is flushed
until a line terminator is found, and then logo construction
continues normally.
52 LOGO hyphen syntax error in input parameters
The beginning or ending dots are out of order, or a parameter is
missing. The buffer is flushed until a line terminator is found, and
then logo construction continues normally.
53 Insufficient memory to create the LOGO
No more room exists in IGP memory to construct a logo for the
size specified. When this occurs, the IGP reverts to Normal
mode. To create space in IGP memory, delete forms with logo
elements (including the logos) that are no longer required.
54 LOGO format or delimiter error
Some type of format or delimiter error was detected in the Logo
command. If this occurs while specifying the size and name of the
logo, the IGP reverts to the Normal mode. If this occurs during the
actual construction of the logo, the buffer is flushed until a line
terminator is found, and then logo construction continues
normally.
55 LOGO call not previously defined
An attempt was made in the Create Form mode to incorporate an
undefined logo into a form. This error is not generated during the
Logo Form mode. When this error occurs, the buffer is flushed
until a line terminator is found, and then forms creation continues
normally.