Printronix LQH-HWTM Printer User Manual


 
Bar Code Errors
271
84 Missing or wrong delimiter - must be a semicolon ;
The delimiter is either wrong or missing. The delimiter expected is
a semicolon.
85 Missing or wrong delimiter - must be a colon :
The delimiter is either wrong or missing. The delimiter expected is
a colon.
86 DENSITY param error - 10, 10A, 10B, 12, 13, 15, 17 or 20
The parameters of the Density command are improperly
specified. The densities currently implemented are 10, 10A, 10B,
12, 13, 15, 17 and 20 characters per inch. The command is
ignored and processing continues.
87 LPI parameters error - must be 6, 8, 9, 10
The parameters of the LPI command are improperly specified.
The only parameters implemented are 6, 8, 9, and 10 lpi. The
command is ignored and processing continues.
88 Bar code type is not supported
The specified bar code type is either misspelled or not supported.
89 EXPAND parameters out of bounds or format error
The parameters of the Expand command are improperly
specified. Either the parameters are out of bounds, or some type
of format error was detected. The command is ignored, and
processing continues.
Bar Code Errors
90 Insufficient memory to store the BARCODE
No more room exists in the IGP memory for another bar code.
The rest of the bar code commands are flushed until the Stop
command is found. Then, processing continues.
91 ALPHA/BARCODE syntax error
Some type of syntax (format) error was detected in the
parameters of the bar code command. This error is usually
caused by one or more of the following:
a. Misspelled keywords;
b. Lowercase used;
c. A missing semicolon;
d. A colon in place of a semicolon;
e. An ending delimiter for the data field was not found;
f. Too many or too few parameters in the command string.
The rest of the command line is flushed until the Stop command
is found. Processing will then continue.
92 BARCODE magnification factor MAG out of bounds or not
allowed
The magnification factor specified in the bar code command is
out of bounds. Refer to the applicable section in the “Bar Codes”
chapter to determine the acceptable magnification values for the
bar code symbol being used.