Sun Microsystems V490 Server User Manual


 
92 Sun Fire V490 Server Administration Guide August 2004
probe-ide Command
The probe-ide command communicates with all Integrated Drive Electronics (IDE)
devices connected to the IDE bus. This is the internal system bus for media devices
such as the DVD drive.
Caution If you used the halt command or the Stop-A key sequence to reach the
ok prompt, then issuing the probe-ide command can hang the system.
The following is sample output from the probe-ide command.
CODE EXAMPLE 6-5 probe-ide Command Output
show-devs Command
The show-devs command lists the hardware device paths for each device in the
firmware device tree.
CODE EXAMPLE 6-6 shows some sample output (edited for
brevity).
CODE EXAMPLE 6-6 show-devs Command Output
ok probe-ide
Device 0 ( Primary Master )
Removable ATAPI Model: TOSHIBA DVD-ROM SD-C2512
Device 1 ( Primary Slave )
Not Present
/pci@9,600000
/pci@9,700000
/pci@8,600000
/pci@8,700000
/memory-controller@3,400000
/SUNW,UltraSPARC-IV@3,0
/memory-controller@1,400000
/SUNW,UltraSPARC-IV@1,0
/virtual-memory
/memory@m0,20
/pci@9,600000/SUNW,qlc@2
/pci@9,600000/network@1
/pci@9,600000/SUNW,qlc@2/fp@0,0
/pci@9,600000/SUNW,qlc@2/fp@0,0/disk