Sun Microsystems V490 Server User Manual


 
96 Sun Fire V490 Server Administration Guide August 2004
In addition to that information, prtdiag with the verbose option (-v) also reports
on front panel status, disk status, fan status, power supplies, hardware revisions,
and system temperatures.
CODE EXAMPLE 6-9 prtdiag Verbose Output
In the event of an overtemperature condition, prtdiag reports an error in the Status
column.
CODE EXAMPLE 6-10 prtdiag Overtemperature Indication Output
Similarly, if there is a failure of a particular component, prtdiag reports a fault in
the appropriate Status column.
CODE EXAMPLE 6-11 prtdiag Fault Indication Output
prtfru Command
The Sun Fire V490 system maintains a hierarchical list of all field-replaceable units
(FRUs) in the system, as well as specific information about various FRUs.
System Temperatures (Celsius):
-------------------------------
Device Temperature Status
---------------------------------------
CPU0 59 OK
CPU2 64 OK
DBP0 22 OK
System Temperatures (Celsius):
-------------------------------
Device Temperature Status
---------------------------------------
CPU0 62 OK
CPU1 102 ERROR
Fan Status:
-----------
Bank RPM Status
---- ----- ------
CPU0 4166 [NO_FAULT]
CPU1 0000 [FAULT]