Sun Microsystems V490 Server User Manual


 
114 Sun Fire V490 Server Administration Guide August 2004
Reference for Terms in Diagnostic
Output
The status and error messages displayed by POST diagnostics and OpenBoot
Diagnostics tests occasionally include acronyms or abbreviations for hardware sub-
components.
TABLE 6-13 is included to assist you in decoding this terminology and
associating the terms with specific FRUs, where appropriate.
TABLE 6-13 Abbreviations or Acronyms in Diagnostic Output
Term Description Associated FRU(s)
ADC Analog-to-Digital Converter PCI riser board
APC Advanced Power Control A function provided
by the SuperIO integrated circuit
PCI riser board
BBC Boot Bus Controller Interface between the
processors and components on many other buses
Centerplane
CDX Data Crossbar Part of the system bus Centerplane
CRC Cyclic Redundancy Check N/A
DAR Address Repeater Part of the system bus Centerplane
DCDS Dual Data Switch Part of the system bus CPU/Memory board
DMA Direct Memory Access – In diagnostic output,
usually refers to a controller on a PCI card
PCI card
EBus A byte-wide bus for low-speed devices Centerplane, PCI riser
board
HBA Host Bus Adapter Centerplane, various
others
I
2
C Inter-Integrated Circuit (also written as I2C) A
bidirectional, two-wire serial data bus. Used
mainly for environmental monitoring and control
Various. See
TABLE 6-12.
I/O Board PCI Riser PCI riser
JTAG Joint Test Access Group – An IEEE subcommittee
standard (1149.1) for scanning system components
N/A
MAC Media Access Controller Hardware address of a
device connected to a network
Centerplane
MII Media Independent Interface – Part of Ethernet
controller
Centerplane
Motherboard Centerplane Centerplane