160 Sun Fire V490 Server Administration Guide • August 2004
What to Do
1. Establish a system controller session.
For instructions, see the Sun Remote System Controller (RSC) User’s Guide, which is
included on the Sun Fire V490 Documentation CD.
2. At the system ok prompt, type:
3. To cause the changes to take effect, type:
The system permanently stores the parameter changes and boots automatically if the
OpenBoot variable auto-boot? is set to true (its default value).
4. To connect to the system console, at the system controller prompt, type:
Note – To reverse the system controller console redirection manually and temporarily
by resetting OpenBoot configuration variables, follow the instructions in “About
OpenBoot Emergency Procedures” on page 54. Otherwise follow the system
controller console exit steps in the section, “How to Restore the Local System
Console” on page 161.
What Next
For instructions on how to use RSC software, see:
■ Sun Remote System Controller (RSC) User’s Guide, which is included on the Sun Fire
V490 Documentation CD
ok setenv diag-out-console true
ok setenv input-device rsc-console
ok setenv output-device rsc-console
ok reset-all
rsc> console