3Com CRWXR10095A Switch User Manual


 
Perform Basic Administrative Tasks 147
Logging—The system log provides event information for monitoring
and troubleshooting. You can send the log information to a local data
buffer on a WX, to the console, to a Telnet session, and to a
configured set of syslog servers.
Tracing—Tracing allows you to review diagnostic information for
debugging MSS. Tracing allows you to review messages about the
status of a specific area of MSS.
Time zone and summertime settings—You can configure the system
time and date statically. You also can configure MSS to offset the time
by an additional hour for daylight savings time or similar summertime
period.
To manage services on a WX switch:
1 Do one of the following:
Open the Modify WX Switch wizard, then select System Information
under Management Services in the organizer list of the System and
Administrative page.
In the Organizer panel, right-click on Management Services under a
WX switch, then select Edit.
2 Select one of the service selections under Management Services,
modify settings, and click Finish.
Distributing Image
and Configuration
Files
You can update the WX system image and configuration files by using
the Distribute Images & Configuration dialog box. You can distribute
system image and configuration files in the following ways:
System image files only
System image and configuration files together
Configuration files only
When you manage images and configurations this way, 3WXM verifies
the configuration and system image compatibility. Compatibility is
verified when you deploy a network plan.