SNC 5100
92 Post-Repair Checklist
6-00020-02
8
Perform the following:
• Start the ADIC
Management
Console Server and
Client.
• Log on with
administrator
privileges.
• Connect to the SNC
5100.
• If you downloaded
new operating
software in Step 5 of
“Updating the SNC
5100” on page 90,
update the
firmware.
• Load the
configuration file
you saved in Step 1
of “Before
Removing or
Replacing the Unit”
on page 82 into the
SNC 5100.
• Restart the SNC
5100.
This step must be performed if you replaced the SNC
5100
For more information, see the ADIC Management
Console User Guide.
9
Reconnect the FC cables
or, if you turned off the
FC hosts, turn them back
on.
If FC1 and/or FC2 Connection Status LEDs for the
attached hosts are not on, check the FC cables.
You may have to change the polarity of the FC cables.
If the problem persists, go to “Start MAP” on page 42.
Table 4-1: Post-Repair Checklist
Step Actions Comments and References