ADIC Scalar 1000 Network Card User Manual


 
Setting the Time and Date 101
6-00020-02
SNC 5100
Setting the Time and Date
Setting the Real Time Clock
Step 1. Use the rtcDateSet command to manually set the Real Time
Clock.
For more information, see the
"rtcDateSet[year],[month],[dayofmonth],[dayofweek],
[hour],[minute],[second]"
command on page 154.
Example:
SN60023 > rtcDateSet 2001,1,26,5,9,30,00
value=0=0x0
SN60023 >
Step 2. Use the dateSetFromRTC command to set the SNC 5100s RTC as
the source of date display.
For more information, see the
"dateSetFromRTC" command on
page 116:
Example:
SN60023 > dateSetFromRTC
value=0=0x0
SN60023 >
Step 3. Use the tzSet command to set the timezone. EST is used in the
example for Eastern Standard Time.
-12 CRC Error - degraded link
-13 Timeout Error
-14 File size error - file size is different than it was supposed to be
-15 Invalid file type
-16 Too many retries - degraded link
-17 Position Error - file data has been lost
Table 12: Zmodem Status Codes
Status
Code
Description