ADIC Scalar 1000 Network Card User Manual


 
Post-Repair Checklist 93
6-00020-02
SNC 5100
10
From the service
terminal, enter the
fcShow command to
show the status of each
FC interface that is
installed and connected.
From the service
terminal, enter the
fcShowDevs
command to show the
SCSI target devices that
are connected as seen by
the Fibre Channel
interface.
In the output of the
fcShow command, look for the
Firmware State column.
If the word Ready does not appear, go to Fibre
Channel MAP on page 61.
Check to see that all SCSI target devices are seen by
each FC interface.
If not, go to SCSI Channel MAP on page 50.
11
Verify that all (or the
designated) target
devices are available to
the host systems.
Use appropriate host system utilities for tape.
See Table 4, Host Utility Software, on page 23.
If Access Control is enabled (Channel Zoning or
SFM) the hosts will only see the devices that have
been assigned to them.
If the designated devices are NOT available, reboot
the host and check again.
If the problem persists, go to Start MAP on page 42.
12
Disconnect the RS-232
cable from the and from
the service terminal.
None.
13
End of repair.
Table 4-1: Post-Repair Checklist
Step Actions Comments and References