ADIC Scalar 1000 Network Card User Manual


 
Installation Procedure 21
6-00020-02
SNC 5100
2
Unpack the SNC 5100. Check the
components against the packing slip.
None.
3
Install into rack or on the desktop. See “” on page 24.
4
Connect the power cord to the SNC
5100.
See Fuses on page 29.
5
Connect the service terminal to the
Service Port and start a terminal
emulation session.
See Connecting to the Service Port on
page 95 for the required parameters.
6
Run the Ethernet cable from the network
hub to the SNC 5100.
If you are using the ADIC Management
Console application, you must configure
an Ethernet environment.
For more information, see the ADIC
Management Console User Guide.
7
Power on the SNC 5100 and observe the
startup messages on the service terminal.
Look for done executing startup script
message. See Startup Message
Reference on page 205.
Within one minute, the RDY LED should
start flashing once per second.
If the done executing startup script
message is not seen or the RDY LED is
not flashing as expected, go the Start
MAP on page 42.
8
Look for the done executing startup
script message on the service terminal,
then power down the SNC 5100.
None.
9
Connect the SCSI cables from the target
devices to the SNC 5100.
Turn on the SCSI target devices.
10
Turn on the SNC 5100. Within one minute, the RDY LED on the
SNC 5100 should start flashing once per
second and the done executing startup
script message should be displayed on
the service terminal.
Table 3: Installation Checklist
Step Actions Comments and References