SNC 5100
16 Supported Devices
6-00020-02
Supported Devices
The architecture and implementation of the SNC 5100 software has full
SCSI-2 and SCSI-3 target and initiator support. The SNC 5100 has support for
disk, tape, and medium changer devices. The product supports all these devices
with the same firmware. Multiple target device type drivers coexist to support
different device types.
For a current list of supported devices, visit
www. adic.com.
Operating Specifications
This section contains the physical, electrical, and environmental specifications
for the product.
The enclosure is designed for strength, durability, and electromagnetic and
radio frequency interference (EMI/RFI) immunity.
The external dimensions are:
• 1.61” high
• 12” deep
• 8.61” wide
• weight: 2.70 kg (~5.93 lb.) with bezel
In order to provide a safety margin and permit adequate cooling, the unit is
fitted with a 12 VDC tach-output blower. Should temperatures exceed
specifications, an environmental alarm violation is sent and logged in a
non-volatile location immune from user erasure, permitting environmental
causes of failure to be determined.
Operating Environment
• Operating Temperature: 10° C to 40° C
• Storage Temperature: -40
° C to 65° C
• Humidity: 10%-90% Operating, Non-Condensing
5%-95% Non-operating, Non-Condensing