SNC 5100
152 Commands
6-00020-02
writes to the flash file system will be lost. This operation is not typically used.
The reboot command should be used to gracefully shutdown and restart the
SNC 5100.
SN60023 > reset
restartScsi [channel]
The
restartScsi command restarts the specified SCSI Channel without
issuing a bus reset.
SN60023 > restartScsi 1
value=0=0x0
SN60023>
ridtag [“value”]
The
ridtag command is used to change the replacement identifier (RID) tag
for the SNC 5100 after it has been replaced by the service representative. This
should be the final step after replacing and verifying that the replacement unit
is performing satisfactorily.
The
sysVpdShow command will display the RID tag. Before replacing the
SNC 5100, you must determine the existing RID tag, if there is one, or the
original serial number if no replacement has been made.
If the ridtag command is entered with a string, that string becomes the RID
tag recorded for the unit.
SN60023 > ridtag “12D345677”
*** value = 0 = 0x0
If a string is not entered, the existing RID tag is displayed.
SN60023 > ridtag
RID Tag = 12D345677
value=0=0x0
SN60023 >
On original equipment, the RID tag will be blank.