ADIC Scalar 1000 Network Card User Manual


 
33
6-00020-02
SNC 5100
Maintenance Action Plans
This section describes the Maintenance Action Plans (MAPs) for the SNC
5100. MAPs exist for all of the SNC 5100s component systems.
If it is clear that a particular component system is at fault in a problem
situation, go directly to the MAP for that component by consulting Table 6.
If it is not clear which component system is at fault in a problem situation,
choose one of the following options:
Work through the Event Codes and Actions in Table 7 on page 35 in order
to determine the appropriate MAP.
Work through the Start MAP on page 42 in order to determine the
appropriate MAP.
Table 6: Maintenance Action Plans Troubleshooting Table
Component Subsystem Go To
If Event Code 42 has been reported Database Full MAP on page 47
If you are unable to access SCSI or Fibre
devices
Device Access MAP on page 48
If SCSI I/O fails or errors on the SCSI bus are
reported
SCSI Channel MAP on page 50
If the SAN Connection LED is off or Fibre
Channel errors are reported
Fibre Channel MAP on page 61
If the SNC 5100 continually reboots or all
LEDs are off
MAP for the SNC 5100 on
page 66
If the temperature Warning or Alarm LEDs are
on
Temperature MAP on page 66
If all LEDs are off or the SNC 5100 fails to
respond to any method of management
Power MAP on page 68
If Client and Server cannot communicate or
the Ethernet LED is off
Ethernet MAP on page 69
If the Client is communicating with the Server,
but the Service Terminal does not respond
Service Port MAP on page 75