ADIC Scalar 1000 Network Card User Manual


 
Service Port MAP 75
6-00020-02
SNC 5100
If both addresses are the same, go to step 33.
Example:
SN60023 > gateAddrGet
Gateway Address set to 192.168.1.1
value=0=0x0
If the network gateway address is incorrect, set it to the value
provided by the network administrator using the
gateAddrSet
command.
For more information, see the
"gateAddrSet" command on page
131.
Step 33. From the service terminal, enter the
reboot command.
Step 34. Wait until the SNC 5100 has finished booting.
Step 35. From the service terminal, use the ping command to PING the IP
address of the ADIC Management Console Server.
For more information, see the ADIC Management Console User
Guide.
Step 36. From the host running the ADIC Management Console Server,
PING the SNC 5100.
If both PING tests succeed, exit this MAP.
If a PING test fails, inform the network administrator to check and
correct the network connection, route tables, and network gateway
addresses for both the ADIC Management Console Server and the
SNC 5100.
Service Port MAP
These steps are performed if the SNC 5100 boots and responds to the ADIC
Management Console, but the Service Port does not respond.
For more information, see the ADIC Management Console User Guide.