ADIC Scalar 1000 Network Card User Manual


 
Commands 151
6-00020-02
SNC 5100
reboot
The
reboot command requests that the SNC 5100 shut down existing
operations and then restart. This is the preferred method of restarting the SNC
5100. There are processes running within the SNC 5100 that may have writes
pending to files within the flash file system. Following a reboot command,
these processes flush their data to the flash file system, and the flash file system
writes all pending data out to the flash memory. Only after all pending data has
successfully been written to flash, will the SNC 5100 start a reset cycle.
SN60023 > reboot
reserveShow [level]
The
reserveShow command outputs a list of devices with reservations.By
adding the flag 1 a list of all devices is output.
SN600393 > reserveShow
Idx Tdev Vendor Product Rev | Reservation ITL
Host's Port Name
----------------------------------------------|--------
value=0=0x0
SN600393 > reserveShow 1
Idx Tdev Vendor Product Rev | Reservation ITL
Host's Port Name
----------------------------------------------|--------
0 0x8fda380 ADIC SNC 5100 40b5 |
1 0x9ffcf08 IBM DNES-309170W SA30 |
value=0=0x0
SN600393 >
reset
The
reset command immediately initiates a reset cycle. Any pending data
Table 15: reserveShow Viewing Levels
Level Explanation
<blank> Show target devices with reservations
1 Show all target devices regardless of whether a reservation is
held or not