ADIC Scalar 1000 Network Card User Manual


 
SNC 5100
118 Commands
6-00020-02
enableCC
To restore the capability to send commands to the command and control
interface (LUN 0), use the
enableCC command. The command is typically
used to re-enable the interface after it was disabled by the disableCC
command.
SN60023 > enableCC
value=0=0x0
SN60023 >
envMonShow
The
envMonShow command lists all of the environmental channel states and
their current values. Use the command
envMonRangeShow to restrict output to
a display of the ranges relevant to each state. The following channels have been
defined:
SN60023 > envMonShow
Channel State Value
------------------------------------------------------
Air Inlet Temperature Nominal 44 C
Channel Name Description
Air Inlet Temp Temperature of the air as it enters the unit
Air Outlet Temp Temperature of the air as it exits the unit
IO Processor Temperature Temperature of the IO Processor
Input Power: ±5 Volts Voltage level of the ±5 input
Input Power: ±12 Volts Voltage level of the ±12 input
Local Power: ±2.5 Volts Voltage level of the local 2.5 supply
Local Power: ±3.3 Volts Voltage level of the local ±3.3 supply
Local Power: ±3.3 Volts
Aux
Voltage level of the local auxiliary ±3.3 supply
Channel Name Description
Fan Fan running (for tachometer fans: RPM of fan)