ADIC Scalar 1000 Network Card User Manual


 
SNC 5100
90 Updating the SNC 5100
6-00020-02
Updating the SNC 5100
Step 1. From the service terminal, enter the normalBoot command.
For more information, see the
"normalBoot" command on page
191.
Step 2. Wait until the SNC 5100 has finished booting.
Step 3. From the service terminal, enter the
version command.
For more information, see the "version" command on page 185.
Step 4. Write down the operating software version number.
Step 5. Determine whether the SNC 5100s firmware version requires an
update.
If an update is required, download the new file or files and the
associated readme.
You will install the new firmware as you complete the "Post-Repair
Checklist".
Step 6. If you replaced the SNC 5100, enter the ridTag command and type
the identifier.
Caution
You must perform this step if you replaced the SNC 5100.
For more information, see the
"ridtag [value]" command on
page 152.
Step 7. Shut down the SNC 5100.
Step 8. Unplug the power cord.
Step 9. Disconnect the RS-232 cable from the SNC 5100.
Step 10. Proceed to "Post-Repair Checklist".