ADIC Scalar 1000 Network Card User Manual


 
Installation Procedure 23
6-00020-02
SNC 5100
Host Utility Software
15
Verify all target devices are available to
the host system.
Use appropriate host system utilities for
disk and tape. See Table 4.
If all devices are NOT available, reboot
host system(s) and check again.
If problem persists, go to Start MAP on
page 42.
Table 4: Host Utility Software
Platform Host Utility Software Name Host Utility Software Function
Windows Disk Administrator
SCSI Adapter control panel applet
Tape Devices control panel applet
show attached devices
show installed scsi adapters
show installed tape device drivers
Solaris
st.conf
1
reboot -- -r
ls/dev/rmt
specify LUNs to be scanned for tape
devices
1
rescan
show mapped tape devices
AIX
lsdev -Cc tape
lsdev -Cc adapter
rmdev - dl fcs[n] -R
where [n] is the
number of the device
cfgmgr
list all tape devices
list all adapters
remove devices no longer present
reconfigure
HP-UX ioscan -C disk scan for devices
NOTE:
1
Because systems vary it is generally not possible to just replace the existing sd.conf or st.conf with a new
one. Therefore you will have to add multiple LUN entries for SCSI ID 0 to sd.conf. After the existing line:
name=st class=scsi target=0 lun=0;
add lines of the form:
name=st class=scsi target=0 lun=1;
until you have as many lines as are needed, one line per storage device or volume. Be sure to increase the
LUN number appropriately.
Table 3: Installation Checklist
Step Actions Comments and References