ADIC Scalar 1000 Network Card User Manual


 
SNC 5100
78 Virtual Private SAN®Scalar Firewall Manager Settings MAP
6-00020-02
For more information, see the "licenseShow" command on page
141.
Example:
License "s2zhq-7xdhd": Valid
Features:
SFM
Value=2=0x2
Step 7. If the output from the licenseShow command shows that SFM is
Valid, as in the example, proceed to Step 8.
If the output from the
licenseShow command shows that SFM is
not Valid, exit this MAP and contact your service representative.
Step 8. Use the ADIC Management Console to verify the host and target
device access settings.
For more information, see the ADIC Management Console User
Guide.
Exit this MAP.
If the ADIC Management Console is not available, you can
temporarily make SFM inactive to verify that the host can access all
devices. Proceed to "Verify Host Access to Devices".
Verify Host Access to Devices
Step 1. Shut down all of the hosts.
Step 2. Enter the
sfmInactive Set command from the service terminal.
For more information, see the
"sfmInactiveSet" command on
page 167.
Step 3. Startup one of the hosts.
Step 4. If the host can access all of the target devices, shut down the host
and repeat steps 2 and 3 for each of the other hosts.
If each host can access all devices then there is a problem with the
Scalar Firewall Manager Access settings. Go to step 5.