ADIC Scalar 1000 Network Card User Manual


 
SCSI Channel MAP 55
6-00020-02
SNC 5100
Improper Device Type
Step 1. Check to be sure that all the devices attached to a single SCSI bus
are of the same type.
Only low voltage differential devices must be attached to low
voltage differential SCSI channels.
When a mix of Ultra2/3 SCSI and Ultra SCSI devices are connected
to a single bus, the bus will run at the Ultra SCSI speed. Because the
bus will auto-adjust to the slowest speed, it is not recommended that
you run both Ultra2/3 SCSI and Ultra SCSI devices on the same
bus.
Caution
If in this procedure you determine that you need to replace a SCSI
device, all I/O to the SNC 5100 must be stopped and it must be
turned off.
Step 2. Replace any improper SCSI device with a proper device.
Step 3. Reconnect the SCSI cable.
Step 4. If you do not have to replace an improper device, go to "Examine
SCSI Cables".
If you replaced any devices, reboot the SNC 5100.
Step 5. After the SNC 5100 finishes booting, enter the scsiShow command
from the service terminal.
For more information, see the
"scsiShow" command on page 160.
Step 6. Compare the list of attached devices with the physical devices.
If not all of the physical devices are shown, go to "Examine SCSI
Cables".
If all of the physical devices are shown, go to "SCSI Health Check".