SNC 5100
40 Event Codes and Actions
6-00020-02
102 1 Temperature change detected since
the last report (event message
indicates the change to High, Very
High, Reduced to High, or OK)
4, 0
106 1 1 Fibre Channel interface failed Health
Check
2
107 1 1 SCSI interface failed Health Check 1
109 1 1 Target device failed Health Check 1
110 1 1 Fibre Channel link status changed 0, 2
111 1 1 Fibre Channel transfer failures
detected since the last report
Caution: error recovery may have
succeeded
0
112 1 1 Blower/Fan is running in Warning or
Alarm Range
4
113 1 1 Power is running in Warning or
Alarm Range
5
114 1 1 Temperature is running in Warning or
Alarm Range
4
115 1 1 Network is running at 10 Mb/sec 7
Heartbeat Event Descriptions
Caution:
These event codes are not
logged in the Event Log. Notification
of these events occurs from the ADIC
Management Console. For more
information on Heartbeat, see the
ADIC Management Console User
Guide.
200
5
N.A. N.A. The Server could not verify the
connection to the SNC 5100
7,3
201
6
N.A. N.A. The Client could not communicate
with the Server
7,9
202
6,7
N.A. N.A. The Server could not communicate
with the Client
7,9
Table 7: Event Codes and Actions
Event
Code
Viewing
Level
1
Default
Trap
Threshold
Description
Action
2