ADIC Scalar 1000 Network Card User Manual


 
Event Codes and Actions 37
6-00020-02
SNC 5100
16 1 1 A SCSI bus reports an unexpected
interrupt
1
17 1 1 Fibre Channel interface reports a LIP
reset was received from a host
0, 2
18 1 1 Fibre Channel interface reports a
system error
2
19 1 1 Fibre Channel interface reports an
error processing a request
2
20 1 1 Fibre Channel interface reports an
error processing a response
2
21 1 1 SNC 5100 processor memory fault
detected
1, 2, 3
22 1 10 Fibre Channel interface detected a
LIP
2
23 2 0 Fibre Channel interface reports a loop
up
0
24 2 0 Fibre Channel interface reports a loop
down
0
25 1 1 SNC 5100 PCI bus parity error
detected
3, 2, 1
26 1 1 SNC 5100 PCI interface error
detected
3, 2, 1
27 2 0 A device has been added to a SCSI
bus
0
28 1 0 A SCSI bus reports a reset has been
detected
0
29 1 1 SNC 5100 has added a device to its
configuration table
Caution: The trap is held off until the
SNC 5100 has been up for 60 seconds
0
30 1 1 SNC 5100 has removed a device from
its configuration
0, 1, 2
31 2 0 SNC 5100 logging service has started 0
Table 7: Event Codes and Actions
Event
Code
Viewing
Level
1
Default
Trap
Threshold
Description
Action
2