Agilent Technologies 87130A Switch User Manual


 
4-76 Agilent 87130A Operating and Service Manual
Remote Operation
Example Speed Calculation
380 OUTPUT 709;ROUT:WIDT .04,(@100,102,104,108);
390 !
400 ! Pulse (:WIDTh) is set to 40 ms for channels 100,102,
410 ! 104, and 108. When :OPEN is sent, 100 and 102
420 ! will OPEN at the same time.
430 ! Channels 104 and 108 will each OPEN at different
440 ! times, because they are connected to different
450 ! drive lines. See the Relay Drive Sequence table
460 ! and Figure 6-1, Timing Diagram.
470 ! In the absence of a pulse width declaration for
480 ! channels 101 and 103, of 30 ms seconds is applied.
490 OUTPUT 709;ROUT:DEL .015,(@100:103);
500 !
510 ! Sensing (:DELay) is set to 15 ms for channels 100
520 ! to 103.
530 OUTPUT 709;ROUT:VER:OFF (@104:107);
540 !
550 ! Example of sensing sacrificed for speed.
560 ! :DELay is invalid for channels 104, 105, 106, 107.
570 !
580 OUTPUT 709;ROUT:WIDT 0.05,(@109:111);
590 !
600 ! Channels 109, 110, 111 set to 50 ms pulse (WIDTh).
610 !
620 OUTPUT 709;ROUT:DEL 0.025,(@109:111);
630 !
640 ! Sensing delays for 109, 110, 111 set to 25 ms.
650 !
660 OUTPUT 709;TRIG:SEQ:DEL 0.02;
670!
680! Sets the power supply recovery time to 20 ms.
690!
700 OUTPUT 709:TRIG:SEQ:DEL?
710 ENTER 709:Trig
720 PRINT Trig
730!
740! Queries the power supply recovery time. Response
should be: 02
750!
760 OUTPUT 709;ROUT:OPEN (@100:111);
770 !