Agilent Technologies 87130A Switch User Manual


 
Agilent 87130A Operating and Service Manual 4-49
Remote Operation
:LABel[?]
:LABel[?]
Syntax
ROUTe :LABEL <label>;
Description
This command specifies a label (32 characters max) to be used when
labeling the group on manual interface screens. Any character may be used
within the quotes as long as its value is between 32 and 127. These values
are treated as ASCII characters.
Example Command ROUTE:PATH:LABEL ATTEN_14,14 dB ATTEN;
The above commands assigns the label 14 dB ATTEN to the previously
defined path with the pathname
ATTEN_14.
Example Query :LABel? <path name>
ROUTE:PATH:LABEL? ATTEN_14;
The query form returns the programmed label:
14 dB ATTEN
Example Command ROUTE:GROUP:LABEL ATTEN,Attenuation;
The above commands assigns the label Attenuation to the group with the
group name
ATTEN.
Example Query :LABel? <group name>
ROUTE:GROUP:LABEL? ATTEN;
The query form returns the programmed label:
Attenuation
:PATH
:GROUP


<path name>
<group name>


