Agilent Technologies 87130A Switch User Manual


 
Agilent 87130A Operating and Service Manual 3-3
Specifications
Performance Specifications
Table 3-2 87130A Environmental Specifications
Environmental Specifications
Temperature
Operating 0 to + 55
°C
Non-operating 40 to 70
°C
Humidity
Operating and
Non-operating 80% relative humidity up to 31
°C decreasing linearly to 50% relative humidity at 40 °C
Altitude
Operating and non-operating 5600 meters (15,000 feet)
Environmental Compatibility Radiated and conducted emission is in compliance with CISPR Pub 11/1990, Group 1, Level A
Environmental Qualification Test
Humidity 5 day, 25 to 40
°C, 50 to 95% relative humidity
Vibration a. Operating: MIL-PRF-28800F, Class 3, par. 4.5.5.3.1 (random, 10 to 500 Hz, 0.21 g rms)
b. Non-operating: swept sine, 5 to 500 Hz, 0.5g, 15 min/axis, 3 axis
c. Non-operating: MIL-PRF-28800F, Class 3, par. 4.5.5.3.1 (random, 10 to 500 Hz, 2.1 g rms)
Shock a. Non-operating, 170 g, 1/2 sine 2ms, 1 drop/face, 6 faces
b. Non-operating, 30 g, trapezoidal, 28 ms, 1 drop/face, 6 faces
Environmental Conditions This product is designed for indoor use in Installation Category II and Pollution Degree 2 per
IEC 1010 and IEC 664, respectively. Enclosure protection is IP 2 0 according to IEC 529.
Line Voltage 100 to 240 Vac
Power Consumption 110 Watts MAX
Weight 6.2 kg (13.7 lb)
Dimensions 10.2 cm (h) x 45.7 cm (w) X 55.9 cm (d)
4 in. x 18 in. x 22.5 in