Agilent Technologies 87130A Switch User Manual


 
4-30 Agilent 87130A Operating and Service Manual
Remote Operation
:CLOSe
:CLOSe
Syntax
ROUTe:CLOSe
ROUTe:PFail:CLOSe[?]
Description
Each channel has a CLOSE or OPEN position. On Agilent relays, the
CLOSE path is the path between the input terminal labeled 2 on the relay
and the input terminal labeled C. It is recognized that CLOSE and OPEN are
arbitrary for this type of switch; they are, however, in keeping with the SCPI
language specification.
Example Command ROUTe:CLOSe (@101,2(0:5),3(1,3,5),406:410);
Sending the above command causes channel 1 on card 1, channels 0 through
5 on card 2, channels 1, 3 and 5 on card 3, and channels 6 through 10 on
card 4 to be closed.
Channels must have DRIVe:ON to be closed or they will be ignored.
During any switching operation (OPEN or CLOSE) the settling bit in the
OPER status register is set (1). It is cleared (0) when the operation
completes.
Example Query ROUTE:CLOSE? (@101,103,105);
Sending the query (question mark) causes the channels in the channel list
parameter to be checked for closed channels. The readback is a list of 1s and
0s separated by commas, one for each channel in the list. A 1 is sent if the
specified channel is closed; otherwise a 0 is sent.
Devices for which sensing is on
(VERify:ON)read back the position in
which they were sensed the last time a switching operation took place.
Devices with sensing off simply read back the currently programmed state
(which, if they havent been switched since power up, will be the state they
were set to at power up). Devices with
DRIVE:OFF read back the last value to
which they were set.
<path name>
<channel list>



<path name>
<channel list>


