silent-time
This command sets the amount of time the management console is inaccessible
after the number of unsuccessful logon attempts exceeds the threshold set by the
password-thresh
command. Use the
no
form to remove the silent time value.
Syntax
silent-time
[seconds]
no silent-time
seconds - The number of seconds to disable console response.
(Range: 0-65535; 0: no silent-time)
Default Setting
The default value is no silent-time.
Command Mode
Line Configuration (console only)
Example
To set the silent time to 60 seconds, enter this command:
Console(config-line)#silent-time 60
Console(config-line)#
Related Commands
password-thresh (23-21)
databits
This command sets the number of data bits per character that are interpreted and
generated by the console port. Use the
no
form to restore the default value.
Syntax
databits {7 | 8}
no databits
• 7 - Seven data bits per character.
• 8 - Eight data bits per character.
Default Setting
8 data bits per character
Command Mode
Line Configuration
Command Usage
The databits command can be used to mask the high bit on input from
devices that generate 7 data bits with parity. If parity is being generated,
specify 7 data bits per character. If no parity is required, specify 8 data bits per
character.
23-22
System Management Commands
23