• Configure Spanning Tree parameters
Configure Class of Service (CoS) priority queuing
Configure up to 6 static or LACP trunks per switch, up to 32 per stack
Enable port mirroring
Set broadcast storm control on any port
Display system information and statistics
Configure any stack unit through the same IP address
Required Connections
The switch provides an RS-232 serial port that enables a connection to a PC or
terminal for monitoring and configuring the switch. A null-modem console cable is
provided with the switch.
Note:
When configuring a stack, connect to the console port on the Master unit.
Attach a VT100-compatible terminal, or a PC running a terminal emulation program
to the switch. You can use the console cable provided with this package, or use a
null-modem cable that complies with the wiring assignments shown in the
Installation Guide.
To connect a terminal to the console port, complete the following steps:
1. Connect the console cable to the serial port on a terminal, or a PC running
terminal emulation software, and tighten the captive retaining screws on the
DB-9 connector.
2. Connect the other end of the cable to the RS-232 serial port on the switch.
3. Make sure the terminal emulation software is set as follows:
Select the appropriate serial port (COM port 1 or COM port 2).
Set to any of the following baud rates: 9600, 19200, 38400, 57600, 115200
(Note: Set to 9600 baud if want to view all the system initialization messages.).
Set the data format to 8 data bits, 1 stop bit, and no parity.
Set flow control to none.
Set the emulation mode to VT100.
When using HyperTerminal, select Terminal keys, not Windows keys.
Notes: 1. Refer to “Line Commands” on page 23-17 for a complete description of
console configuration options.
2.
Once you have set up the terminal correctly, the console login screen will be
displayed.
For a description of how to use the CLI, see “Using the Command Line Interface” on
page 21-1. For a list of all the CLI commands and detailed information on using the
CLI, refer to “Command Groups” on page 21-10.
2-2
Initial Configuration