Barco R59770057 Projector User Manual


 
14. Service menu
4. Use the or key to select Overtemp DMD and press ENTER to toggle between [On] and [Off].
On When temperature is too high, lamp mode is switched from 4 to 2 lamps. The 4 lamps mode can only be restored
after switching rst to standby and restarting the projector.
If the temperature exceeds 64 °C, the projector is switched to standby.
Off for a temperature between 60 and 64 °C the projector continues in normal operation but the warning is set on the
LCD display. Once the temperature is higher then 64 °C, then the projector is switched to standby.
The following text is displayed on the LCD: “DMD temperature to high. Please, check cooling liquid level ! Check
dust lters ! Press any key to conrm.”
Image 14-55
Image 14-56
Image 14-57
R59770057 CLM HD8 15/03/2010 165