16. Servicing
Image 16-9
Take out the lamp
For recycling guidelines of the lamp, see "Recycling guidelines", page 8.
16.6 Mounting a new lamp unit
About the lamp units
All four lamp units are equal. A spare lamp can be inserted in any position without problems. See spare part list for the order
numbers.
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Never attempt to disassemble the la
mp from its housing or to dispose of it. Due to its high internal
pressure, the lamp may explode in either hot or cold states if improperly handled. For recycling guidelines,
see "Recycling guidelines", page 8.
CAUTION: Never touch the reflector or the lamp bulb with your fingers. That will reduce the lifetime of the
lamp.
Never touch the UV filter when a lamp is removed.
Necessary tools
No tools.
How to insert a lamp unit
1. Insert the lamp vertically into the housing, with the front of the lamp facing the middle of the projector.
R59770057 CLM HD8 15/03/2010