Brocade Communications Systems 53-1002373-02 Network Router User Manual


 
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 27
53-1002373-02
Router modules
1
8x10GE-X interface modules
The 8x10GE-X interface modules provide 8 ports of 10 Gigabit Ethernet with support for 1M IPv4
routes in hardware.
NOTE
Gen-2 8x10GE-X modules require high speed switch fabric modules to operate. You can replace
switch fabric modules with high-speed switch fabric modules while the system is powered on and
running. For more information about high-speed switch fabric modules, refer to “High-speed switch
fabric modules” on page 50.
Figure 16 shows the faceplate of the 8x10GE-X module.
FIGURE 16 8x10GE-X module faceplate
8x10GE-X modules support SFP+ optics only; they do not support SFP or CFP optics. For a list of
supported SFP+ optics, refer to the latest version of the Brocade Optics Family Data Sheet,
available online in the following location:
http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_DS.p
df
MLXe-16 six four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
for 3+3 redundancy, install four 1800W PSU
seven to eight a minimum of five 1200W PSU
for 4+4 redundancy, install eight 1800W PSU
for 5+3 redundancy, install eight 1200W PSU
Brocade NetIron
XMR 1600
eight (1x100GE) four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
MLXe-32 twelve four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU
thirteen to sixteen five 2400W PSU
for 5+3 redundancy, install eight 2400W PSU
four 3000W PSU
for 4x4 redundancy, instal eight 3000W PSU
Brocade NetIron
XMR 3200
sixteen (1x100GE) four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU
TABLE 6 Power supply requirements for 100xGbE modules (Continued)
Router type Number of 100xGbE
modules installed
Power supply requirements (minimum required-redundancy requirements)
1
2
7
8