Brocade Communications Systems 53-1002373-02 Network Router User Manual


 
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 31
53-1002373-02
Router modules
1
Power supply requirements for Gen-1 2-port or 4-port 10 Gbps Ethernet interface modules
Table 10 lists the power supply requirements for each type of router when installing Gen-1 2-port or
4-port 10 Gbps Ethernet interface modules.
TABLE 10 Power supply requirements for Gen-1 2-port or 4-port 10 Gbps Ethernet interface modules
Router type Number of Gen-1
2-port or 4-port Gbps
Ethernet interface
modules installed
Power supply requirements
MLXe-4 three one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
four two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
MLX-4 and
Brocade NetIron
XMR 4000
four one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
MLXe-8 seven two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
eight three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
Brocade NetIron
XMR 8000
eight two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
All 16-slot routers sixteen four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
All 32-slot routers thirty-two four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU