Brocade Communications Systems 53-1002373-02 Network Router User Manual


 
40 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
Router modules
1
Power supply requirements for BR-MLX-1GFx24-X and BR-MLX-1GFx24-X-ML interface modules
Table 18 lists the power supply requirements for each type of router when installing 24-port 1 Gbps
fiber interface modules.
20-port 100/1000 Ethernet interface module
Figure 23 shows the front panel of the 20-port 100/1000 Gbps Ethernet SFP interface module.
FIGURE 23 20-port 100/1000 Ethernet module front panel
TABLE 18 Power supply requirements for 24-port 1 Gbps fiber interface module
Router type Number of 24-port 1
Gbps fiber interface
module installed
Power supply requirements
MLXe-4 three one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
four two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
MLX-4 and
Brocade NetIron
XMR 4000
four one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
MLXe-8 seven two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
eight three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
Brocade NetIron
XMR 8000
eight two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
All 16-slot routers sixteen four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
All 32-slot routers thirty-two four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU