Error code AD
DMA transfer error
Error code AE
CCD unit home position sensor is not turned on.
Error code AF
CCD unit home position sensor is not turned off.
Scan Unable AD
Remove the original document. Turn the power off, then on again.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
2 CCD unit failure Replace the CCD unit.
Scan Unable AE
See Troubleshooting and routine maintenance chapter in User's
Guide.
User Check
Check that the scanner lock lever is unlocked.
Step Cause Remedy
1 Drive PCB failure Replace the drive PCB.
2 Belt broken Replace the belt.
3 Home position sensor failure Replace the home position sensor.
4 Tab of CCD unit broken Replace the CCD unit.
5 Scanner motor failure Replace the scanner motor.
6 Main PCB failure Replace the main PCB ASSY.
Scanner Locked
Open the Document Cover and release Scanner lock lever. Press Stop
key.
User Check
Check that the scanner lock lever is unlocked.
Step Cause Remedy
1 Drive PCB failure Replace the drive PCB.
2 Belt broken Replace the belt.
3 Home position sensor failure Replace the home position sensor.
4 Scanner motor failure Replace the scanner motor.
5 Main PCB failure Replace the main PCB ASSY.