Brother DCP-8080DN/8085DN Fax Machine User Manual


 
App. 1-9
Confidential
<WSW04>
Selectors 6 and 8: Break time length for flash function
These selectors set the break time length. This setting is effective only when the flash
function is selected for the [Search/Speed Dial] button by using the function switch.
Selector No. Function Setting and Specifications
1
Earth function in transfer facility
(Not used.)
0: Provided 1: Not provided
2
3
Dual tone detection frequency in
ICM recording (Not used.)
No. 2 3
0 0: 350 and 440 Hz (A)
0 1: 440 and 480 Hz (B)
1 0: 480 and 620 Hz (C)
1 1: 480 and 620 Hz (C)
4
Dual tone detection sensitivity in
ICM recording (Not used.)
0: Normal 1: High
5
Length of time added to time
designated by selectors 3 and 4
on the WSW 24 (time between
CML ON and pseudo ring
backtone return).
0: Not added 1: +4 seconds added
6
I
8
Break time length for flash
function
No. 6 7 8
0 0 0: 80 ms
0 0 1: 100 ms
0 1 0: 110 ms
0 1 1: 120 ms
1 0 0: 200 ms
1 0 1: 250 ms
1 1 0: 500 ms
1 1 1: 700 ms
Note:
Selectors 1 and 5 through 8 are not applicable in those countries where no transfer
facility is supported.