5. OTHER SERVICE FUNCTIONS
5.1 Resetting the Periodical Replacement Parts Life
Resetting the Life Counter of the Fuser Unit
<Function>
This function allows you to reset the page counter of the fuser unit and increase the number
of replacement times by one.
<Operating Procedure>
(1) Press the [3] and [9] keys at the same time in the ready state.
The “Reset Menu” will appear on the LCD.
(2) Press the [ ] button a few times to select “Fuser”.
(3) Press the [OK] button.
The “1. Reset / 2. Exit” will appear on the LCD.
(4) Press the [1] key when resetting the life counter of the fuser unit. Press the [2] key if not
resetting.
(5) The “Accepted” will appear on the LCD if pressing the [1] key. The page counter of the
fuser unit is reset, and the number of replacement times is increased by one. Then, the
machine returns to the ready state. If pressing the [2] key, the machine do not reset the
page counter and the “Fuser” will appear on the LCD.
Resetting the Life Counter of the Drum Unit
<Function>
This function allows you to reset the page counter of the drum unit and increase the number
of replacement times by one.
<Operating Procedure>
(1) Press the [3] and [9] keys at the same time in the ready state.
The “Reset Menu” will appear on the LCD.
(2) Press the [ ] button a few times to select “Drum”.
(3) Press the [OK] button.
The “1. Reset / 2. Exit” will appear on the LCD.
(4) Press the [1] key when resetting the life counter of the drum unit. Press the [2] key if not
resetting.
(5) The “Accepted” will appear on the LCD if pressing the [1] key. The page counter of the
drum unit is reset, and the number of replacement times is increased by one. Then, the
machine returns to the ready state. If pressing the [2] key, the machine do not reset the
page counter and the “Drum” will appear on the LCD.