Brother DCP-8080DN/8085DN Fax Machine User Manual


 
App. 1-7
Confidential
<WSW03>
* PABX: Private automatic branch exchange
Selectors 1 and 5: CNG detection when sharing a modular wall socket with a telephone
These selectors determine whether or not the machine detects a CNG signal when a line is
connected to a telephone sharing a modular wall socket with the machine. Upon detection
of CNG signals by the number of cycles specified by these selectors, the machine
interprets CNG as an effective signal and then starts FAX reception.
Selectors 2 through 4:Detection time length of PABX dial tone, required for starting
dialing
Upon detection of the PABX dial tone for the time length set by these selectors, the
machine starts dialing. These selectors are effective only when both selectors 6 and 7 are
set to "1" (Detection).
Selector No. Function Setting and Specifications
1
CNG detection when sharing a
modular wall socket with a
telephone
0: A 1: B
2
I
4
Detection time length of PABX*
dial tone, required for starting
dialing
No. 2 3 4
0 0 0: 50 ms
0 0 1: 210 ms
0 1 0: 500 ms
0 1 1: 800 ms
1 0 0: 900 ms
1 0 1: 1.5 sec.
1 1 0: 2.0 sec.
1 1 1: 2.5 sec
5
CNG detection when sharing a
modular wall socket with a
telephone
0: A 1: B
6
7
Dial tone detection in PABX*
No. 6 7
0 0 : No detection (3.5 sec. wait)
0 1 : No detection (5 sec. wait)
1 0 : No detection (7 sec. wait)
1 1 : Detection (Frequency only)
8 Not used.
Note:
Selectors 2 through 4, 6 and 7 are not applicable where no PABX is installed.
Selector
Cycle
No. 1 No. 5
0 (A) 0 (A) 0.5 cycle
0 (A) 1 (B) 1.0 cycle
1 (A) 0 (A) 1.5 cycle
1 (B) 1 (B) 2.0 cycle