Brother DCP-8080DN/8085DN Fax Machine User Manual


 
App. 1-72
Confidential
<WSW66>
(page)
Selectors 1 through 8: K drum life end
(Life value - 5000) ÷ 500 = Set value
Enter the value of each selector in binary number, and then plug it into the set value of the
above formula and calculate the life value.
For example, when set the life value to 15000 pages, enter the “00010100” in binary
number (“10” in decimal number).
<WSW67>
<WSW68>
(page)
Selectors 1 through 8: Fuser unit life end
Life value ÷ 500 = Set value
Enter the value of each selector in binary number, and then plug it into the set value of the
above formula and calculate the life value.
For example, when set the life value to 15000 pages, enter the “00010100” in binary
number (“10” in decimal number).
Selector No. Function Setting and Specifications
1
I
8
Drum life end
(Life value - 5000) ÷ 500 = Set value
For example
No.12345678
00000000: Life value 5000
00000001: Life value 5000
00000010: Life value 6000
00010100: Life value 15000
· · · ·
Selector No. Function Setting and Specifications
1
I
8
CMY drum life end
(Not used.)
Selector No. Function Setting and Specifications
1
I
8
Fuser unit life end
Life value ÷ 5000 = Set value
For example
No.12345678
00000000: Life value 5000
00000001: Life value 5000
00000010: Life value 6000
00010100: Life value 15000
· · · ·