App. 1-21
Confidential
<WSW15>
• Selectors 1 through 6: Redial interval and No. of redialings
The machine redials by the number of times set by selectors 3 through 6 at intervals set by
selectors 1 and 2.
• Selector 8: CRP option
If a command error occurs in the machine (calling station), the machine usually waits for
three seconds and then makes a retry three times. This CRP option is a request command
that can be sent from the called station for requesting the calling station to retry the failed
command immediately.
Selector No. Function Setting and Specifications
1
2
Redial interval
No. 1 2
00: 5 min.
01: 1 min.
10: 2 min.
11: 3 min.
3
I
6
No. of redialings
No. 3 4 5 6
0000: 16 times
0001: 1 times
0010: 2 times
0011: 3 times
|
1111: 15 times
7(Not used.)
8 CRP option 0: Disable 1: Enable