Compaq AA-Q88CE-TE Network Router User Manual


 
DISPLAY NUMERIC
The
keyword
can be one of the following:
Keyword Meaning
NODE Node data items
LINK Link data items
FACILITY Facility data items
PROCESS Process data items
PARTITION Partition data items
FE_TRANSACTION Frontend transaction data items
TR_TRANSACTION Backend transaction data items
BE_TRANSACTION Router transaction data items
/BELL[=Boolean-expression]
/NOBELL (D)
Sends a bell character to the terminal if
Boolean-expression
evaluates to True
(non-zero).
/BLANK[=Boolean-expression]
/NOBLANK (D)
Specifies that the displayed value is replaced by blanks if
Boolean-expression
evaluates to True (non-zero).
/BLINK[=Boolean-expression]
/NOBLINK (D)
Specifies that the displayed value blinks if
Boolean-expression
evaluates to True
(non-zero).
/BOLD[=Boolean-expression]
/NOBOLD (D)
Specifies that the item is displayed in high intensity if
Boolean-expression
evaluates to True (non-zero).
/DAMPING[=damping-factor]
/NODAMPING (D)
Specifies that the value displayed is to fluctuate more slowly than the raw
measured value. The default for
damping-factor
is one. Damping is only
relevant if
/VALUE=CURRENT
.
/DECIMALS[=decimal-places]
/DECIMALS=0 (D)
Specifies the number of digits to appear after the decimal point when displaying a
numeric. The default for
decimal-places
is zero, that is, numbers are displayed
as integers.
/LABEL=text
/NOLABEL (D)
Specifies the text used to label the value being displayed. Symbols are substituted
at display time. (See Section A.2, Substitution Symbols).
RTR Command Line Interface 6–73