Dell R300 Network Card User Manual


 
Troubleshooting Your System 137
8
Reseat the memory modules in their sockets. See "Installing Memory
Modules" on page 104.
9
Close the system. See "Opening and Closing the System" on page 68.
10
Reconnect the system to its electrical outlet, and turn on the system and
attached peripherals.
11
Enter the System Setup program and check the system memory setting.
See "Entering the System Setup Program" on page 45.
If the amount of memory installed still does not match the system
memory setting, proceed to the next step.
12
Turn off the system and attached peripherals, and disconnect the system
from its electrical outlet.
13
Open the system. See "Opening and Closing the System" on page 68.
14
If a diagnostic test or error message indicates a specific memory module as
faulty, swap or replace the module. Otherwise, swap the memory module
in the first DIMM socket with a module of the same type and capacity that
is known to be good. See "Installing Memory Modules" on page 104.
15
Close the system. See "Opening and Closing the System" on page 68.
16
Reconnect the system to its electrical outlet, and turn on the system and
attached peripherals.
17
As the system boots, observe any error message that appears and the
diagnostic indicators on the front of the system.
18
If the memory problem is still indicated, repeat step 12 through step 17 for
each memory module installed.
If the problem persists, see "Getting Help" on page 165.
Troubleshooting an Internal USB Key
Problem
System cannot read data from a USB memory key.