Dell R300 Network Card User Manual


 
30 About Your System
E1A15 SAS Cable C SAS cable C is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 165.
E1A18 PDB Ctrl
Cable
Control cable for the power
distribution board (PDB) is
missing or bad
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 165.
E2010 No Memory No memory is installed in
the system.
Install memory. See
"Installing Memory
Modules" on page 104.
E2011 Mem Config
Err
Memory detected, but is not
configurable. Error detected
during memory
configuration.
See "Troubleshooting
System Memory" on
page 135.
E2012 Unusable
Memory
Memory is configured, but
not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 135..
E2013 Shadow BIOS
Fail
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 135.
E2014 CMOS Fail CMOS failure. CMOS RAM
not functioning properly.
See "Getting Help" on
page 165.
E2015 DMA
Controller
DMA controller failure. See "Getting Help" on
page 165.
E2016 Int
Controller
Interrupt controller failure. See "Getting Help" on
page 165.
E2017 Timer Fail Timer refresh failure. See "Getting Help" on
page 165.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions