Dell R300 Network Card User Manual


 
About Your System 25
E1410 CPU # IERR Specified microprocessor is
reporting an internal error.
See your system’s
"Information Update
Tech Sheet" located on
support.dell.com for the
most current system
information. If the
problem persists, see
"Getting Help" on
page 165.
E1414 CPU #
Thermtrip
Specified microprocessor is
out of acceptable
temperature range and has
halted operation.
See "Troubleshooting
System Cooling
Problems" on page 134. If
the problem persists,
ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 149.
NOTE: The LCD continues
to display this message
until the system’s power
cord is disconnected and
reconnected to the AC
power source, or the SEL is
cleared using either Server
Assistant or the BMC
Management Utility. See
the Dell OpenManage
Baseboard Management
Controller User’s Guide for
information about these
utilities.
E1418 CPU #
Presence
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
See "Troubleshooting the
Microprocessors" on
page 149.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions